Hybrid Inverter

X3 ULTRA

X3 ULTRA

15kW / 19.9kW / 20kW / 25kW / 30kW

Assured Reliability


  • Battery terminal temperature detection

  • IP66 protection degree

  • Type II SPD on AC&DC side

  • Optional AFCI protection







High Performance


  • 200% PV oversizing and up to 110% AC output

  • 200% EPS overload for 10s

  • Max. 60A charging / discharging current

  • Low start-up voltage for longer operation



Smart Management


  • Single unit UPS-level switchover time<10ms

  • Built-in shadow tracking

  • Smart loads management(e.g., heat pump, smart EV charger)

  • Loads respond time within 0.3 s

  • VPP ready with a variety of compatibility

  • (OpenADR, IEEE2030.5, FCAS, API)*




Flexible Adaptability

  • Max. 10pcs parallel for on-grid and off-grid

  • Microgrid and generator function for versatile operations

  • Max. 36A PV input per MPPT, optimized for high-power solar panel



Why X3 ULTRA

Introduces a new C&I energy storage solution, suitable for factories, malls, offices, and warehouse. 

With 2/3 MPPTs, it maximizes power generation, enhancing compatibility with complex solar systems. 

Even if one MPPT encounters a fault, it won't affect the operation of other arrays.


200% oversized PV input = 100% AC Output + 100% Battery Storage

We ensure every unit of solar power is fully utilized, converted into AC output and stored in batteries efficiently. 

Power is allocated independently to each phase, controllable down to 0W per phase, with a max.10kW output on a single phase, reducing grid reliance.


Highlighting our micro-gird function. 

The micro-grid feature enables the hybrid inverter to simulate the grid and activate the string inverter when off-grid. 

By connecting the string inverter to the hybrid inverter's EPS port, it can use PV or battery energy to power the string inverter during utility outages.


Leveraging real-time data detection through our SOLAX Cloud streamlines commercial and industrial management processes.



15kW
15KP
30kW
25kW
20KP
19.9kW
20kW
ParameterX3-ULT-15K
Max. recommended PV array power30 kWp
Max. PV input voltage1000 V
Nominal PV input voltage600 V
Operating voltage range120 ~ 950 V
MPPT voltage range160 ~ 950 V
Start-up voltage200 V
No. of MPP trackers / Strings per MPP tracker2 / (2 / 2)
Max. input current per MPPT (MPPT1/2/3)36 A / 36 A
Max. input short circuit current per MPPT (MPPT1/2/3)45 A / 45 A
Rated output power15000 W (AS4777 14999 W)
Rated output current21.8 A
Max. output apparent power16500 VA (AS4777 14999 VA)
Max. output continuous current24.0 A (AS4777 21.8 A)
Nominal AC voltage3 / N / PE, 220 / 380 V
Max. AC input apparent power15000 VA
Max. AC input current21.8 A
Nominal AC frequency50 Hz / 60 Hz
Adjustable Power Factor range~1 (0.8 lagging to 0.8 leading)
THDi (rated power)<3%
Battery typeLithium
Battery voltage range120 ~ 800 V



ParameterX3-ULT-15KP
Max. recommended PV array power30 kWp
Max. PV input voltage1000 V
Nominal PV input voltage600 V
Operating voltage range120 ~ 950 V
MPPT voltage range160 ~ 950 V
Start-up voltage200 V
No. of MPP trackers / Strings per MPP tracker2 / (2 / 2)
Max. input current per MPPT (MPPT1/2/3)36 A / 36 A
Max. input short circuit current per MPPT (MPPT1/2/3)45 A / 45 A
Rated output power15000 W (AS4777 14999 W)
Rated output current21.8 A
Max. output apparent power16500 VA (AS4777 14999 VA)
Max. output continuous current24.0 A (AS4777 21.8 A)
Nominal AC voltage3 / N / PE, 220 / 380 V
Max. AC input apparent power15000 VA
Max. AC input current21.8 A
Nominal AC frequency50 Hz / 60 Hz
Adjustable Power Factor range~1 (0.8 lagging to 0.8 leading)
THDi (rated power)<3%
Battery typeLithium
Battery voltage range120 ~ 800 V







ParameterX3-ULT-30K
Max. recommended PV array power60 kWp
Max. PV input voltage1000 V
Nominal PV input voltage600 V
Operating voltage range120 ~ 950 V
MPPT voltage range160 ~ 950 V
Start-up voltage200 V
No. of MPP trackers / Strings per MPP tracker3 / (2 / 2 / 2)
Max. input current per MPPT (MPPT1/2/3)36 A / 36 A / 36 A
Max. input short circuit current per MPPT (MPPT1/2/3)45 A / 45 A / 45 A
Rated output power30000 W (AS4777 29999 W, VDE 4105 29900 W)
Rated output current43.5 A
Max. output apparent power30000 VA (AS4777 29999 VA, VDE 4105 29900 VA)
Max. output continuous current43.5 A
Nominal AC voltage3 / N / PE, 230 / 400 V
Max. AC input apparent power30000 VA
Max. AC input current43.5 A
Nominal AC frequency50 Hz / 60 Hz
Adjustable Power Factor range~1 (0.8 lagging to 0.8 leading)
THDi (rated power)<3%
Battery typeLithium
Battery voltage range120 ~ 800 V





ParameterX3-ULT-25K
Max. recommended PV array power50 kWp
Max. PV input voltage1000 V
Nominal PV input voltage600 V
Operating voltage range120 ~ 950 V
MPPT voltage range160 ~ 950 V
Start-up voltage200 V
No. of MPP trackers / Strings per MPP tracker3 / (2 / 2 / 2)
Max. input current per MPPT (MPPT1/2/3)36 A / 36 A / 36 A
Max. input short circuit current per MPPT (MPPT1/2/3)45 A / 45 A / 45 A
Rated output power25000 W (VDE 4105 24900 W)
Rated output current36.3 A
Max. output apparent power27500 VA (VDE 4105 24900 VA)
Max. output continuous current39.9 A (VDE 4105 36.3 A)
Nominal AC voltage3 / N / PE, 230 / 400 V
Max. AC input apparent power25000 VA
Max. AC input current36.3 A
Nominal AC frequency50 Hz / 60 Hz
Adjustable Power Factor range~1 (0.8 lagging to 0.8 leading)
THDi (rated power)<3%
Battery typeLithium
Battery voltage range120 ~ 800 V





ParameterX3-ULT-20KP
Max. recommended PV array power40 kWp
Max. PV input voltage1000 V
Nominal PV input voltage600 V
Operating voltage range120 ~ 950 V
MPPT voltage range160 ~ 950 V
Start-up voltage200 V
No. of MPP trackers / Strings per MPP tracker2 / (2 / 2)
Max. input current per MPPT (MPPT1/2/3)36 A / 36 A
Max. input short circuit current per MPPT (MPPT1/2/3)45 A / 45 A
Rated output power20000 W
Rated output current29.0 A
Max. output apparent power22000 VA
Max. output continuous current31.9 A
Nominal AC voltage3 / N / PE, 230 / 400 V
Max. AC input apparent power20000 VA
Max. AC input current29.0 A
Nominal AC frequency50 Hz / 60 Hz
Adjustable Power Factor range~1 (0.8 lagging to 0.8 leading)
THDi (rated power)<3%
Battery typeLithium
Battery voltage range120 ~ 800 V






ParameterX3-ULT-19.9K
Max. recommended PV array power40 kWp
Max. PV input voltage1000 V
Nominal PV input voltage600 V
Operating voltage range120 ~ 950 V
MPPT voltage range160 ~ 950 V
Start-up voltage200 V
No. of MPP trackers / Strings per MPP tracker3 / (2 / 2 / 2)
Max. input current per MPPT (MPPT1/2/3)36 A / 36 A / 36 A
Max. input short circuit current per MPPT (MPPT1/2/3)45 A / 45 A / 45 A
Rated output power19999 W
Rated output current29.0 A
Max. output apparent power19999 VA
Max. output continuous current29.0 A
Nominal AC voltage3 / N / PE, 230 / 400 V
Max. AC input apparent power19999 VA
Max. AC input current29.0 A
Nominal AC frequency50 Hz / 60 Hz
Adjustable Power Factor range~1 (0.8 lagging to 0.8 leading)
THDi (rated power)<3%
Battery typeLithium
Battery voltage range120 ~ 800 V





ParameterX3-ULT-20K
Max. recommended PV array power40 kWp
Max. PV input voltage1000 V
Nominal PV input voltage600 V
Operating voltage range120 ~ 950 V
MPPT voltage range160 ~ 950 V
Start-up voltage200 V
No. of MPP trackers / Strings per MPP tracker2 / (2 / 2)
Max. input current per MPPT (MPPT1/2/3)36 A / 36 A
Max. input short circuit current per MPPT (MPPT1/2/3)45 A / 45 A
Rated output power20000 W
Rated output current29.0 A
Max. output apparent power22000 VA
Max. output continuous current31.9 A
Nominal AC voltage3 / N / PE, 230 / 400 V
Max. AC input apparent power20000 VA
Max. AC input current29.0 A
Nominal AC frequency50 Hz / 60 Hz
Adjustable Power Factor range~1 (0.8 lagging to 0.8 leading)
THDi (rated power)<3%
Battery typeLithium
Battery voltage range120 ~ 800 V