3.0kW / 3.7kW / 4.0kW
4.6kW / 5.0kW / 6.0kW
Max. 10pcs parallel for on-grid and off-grid*
Microgrid and generator function for versatile operations*
Max. 16A DC input current for high-power solar panel
Single unit UPS-level switchover time < 4 ms
Global MPP scan for optimal energy harvest
Smart loads management
CT compatibility with fast load response in just 0.3 seconds
200% PV oversizing and up to 110% AC output
200% peak EPS power for 10s
Max. 120A charging / discharging current
Low start-up voltage for longer operation
Battery terminal temperature detection
IP65 protection degree
Type II SPD on AC&DC side
Optional AFCI protection*
Unleash the full potential of our advanced hybrid inverter with 200% PV oversizing, high power input, and flexible compatibility with multiple battery types. Experience UPS-level switching time, EPS output of up to 200% for 10s, and future-ready generator compatibility. The inverter features a 16A DC single string input current supporting high-power solar panels. Enjoy intelligent features like built-in shadow tracking, a user-friendly LCD color screen, and smart loads management. Rest easy with safety features, including battery terminal temperature detection, IP65 protection, integrated SPD, and optional AFCI protection. Elevate your energy system with our reliable and adaptable solar inverter.
Model | X1-HYB-3.0-LV |
Max. recommended PV array power (Wp) | 6000 |
Max. PV input voltage (V) | 550 |
Nominal PV input voltage (V) | 360 |
MPPT voltage range (V) | 80 ~ 520 |
Start-up voltage (V) | 110 |
No. of MPP trackers / Strings per MPP tracker | 2/(1/1) |
Max. input current per MPPT (A) | 16/16 |
Max. input short circuit current per MPPT (A) | 20/20 |
Rated output power (W) | 3000 |
Max. output apparent power (VA) | 3300 |
Max. output continuous current (A) | 15 |
Nominal AC voltage (V) | 1/N/PE, 220/230/240 |
Max. AC input apparent power (VA) | 6000 |
Max. AC input current (A) | 26.1 |
Nominal AC frequency (Hz) | 50 / 60 |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <2% |
Model | X1-HYB-3.7-LV |
Max. recommended PV array power (Wp) | 7360 |
Max. PV input voltage (V) | 550 |
Nominal PV input voltage (V) | 360 |
MPPT voltage range (V) | 80 ~ 520 |
Start-up voltage (V) | 110 |
No. of MPP trackers / Strings per MPP tracker | 2/(1/1) |
Max. input current per MPPT (A) | 16/16 |
Max. input short circuit current per MPPT (A) | 20/20 |
Rated output power (W) | 3680 |
Max. output apparent power (VA) | 3680 |
Max. output continuous current (A) | 16 |
Nominal AC voltage (V) | 1/N/PE, 220/230/240 |
Max. AC input apparent power (VA) | 7360 |
Max. AC input current (A) | 32 |
Nominal AC frequency (Hz) | 50 / 60 |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <2% |
Model | X1-HYB-4.0-LV |
Max. recommended PV array power (Wp) | 8000 |
Max. PV input voltage (V) | 550 |
Nominal PV input voltage (V) | 360 |
MPPT voltage range (V) | 80 ~ 520 |
Start-up voltage (V) | 110 |
No. of MPP trackers / Strings per MPP tracker | 2/(1/1) |
Max. input current per MPPT (A) | 16/16 |
Max. input short circuit current per MPPT (A) | 20/20 |
Rated output power (W) | 4000 |
Max. output apparent power (VA) | 4400 |
Max. output continuous current (A) | 20 |
Nominal AC voltage (V) | 1/N/PE, 220/230/240 |
Max. AC input apparent power (VA) | 8000 |
Max. AC input current (A) | 34.8 |
Nominal AC frequency (Hz) | 50 / 60 |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <2% |
Model | X1-HYB-5.0-LV |
Max. recommended PV array power (Wp) | 10000 |
Max. PV input voltage (V) | 550 |
Nominal PV input voltage (V) | 360 |
MPPT voltage range (V) | 80 ~ 520 |
Start-up voltage (V) | 110 |
No. of MPP trackers / Strings per MPP tracker | 2/(1/1) |
Max. input current per MPPT (A) | 16/16 |
Max. input short circuit current per MPPT (A) | 20/20 |
Rated output power (W) | 5000 |
Max. output apparent power (VA) | 5000 |
Max. output continuous current (A) | 22.7 |
Nominal AC voltage (V) | 1/N/PE, 220/230/240 |
Max. AC input apparent power (VA) | 9200 |
Max. AC input current (A) | 40 |
Nominal AC frequency (Hz) | 50 / 60 |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <2% |
Model | X1-HYB-6.0-LV |
Max. recommended PV array power (Wp) | 12000 |
Max. PV input voltage (V) | 550 |
Nominal PV input voltage (V) | 360 |
MPPT voltage range (V) | 80 ~ 520 |
Start-up voltage (V) | 110 |
No. of MPP trackers / Strings per MPP tracker | 2/(1/1) |
Max. input current per MPPT (A) | 16/16 |
Max. input short circuit current per MPPT (A) | 20/20 |
Rated output power (W) | 6000 |
Max. output apparent power (VA) | 6000 |
Max. output continuous current (A) | 27.3 |
Nominal AC voltage (V) | 1/N/PE, 220/230/240 |
Max. AC input apparent power (VA) | 12000 |
Max. AC input current (A) | 40.0 A |
Nominal AC frequency (Hz) | 50 / 60 |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <2% |